Testing and Certifications
Arxx has the most testing and certifications in
the industry. Check out the following testing, certifications
and requirement and you'll know why Arxx is the Number One ICF:
Fire Resistance
- UL/ULC listing of Fire Resistance Ratings in accordance with
ASTM E119 and CAN/ULC-S101
- a fire retardant is added to the Arxx forms during manufacturing
- exceeds Classification A as tested in accordance with CAN4-S124-M85
when covered with one layer ½" (12.7 mm) GWB
- when protected by ½" conventional GWB, Arxx
meets the requirements of the UBC Standard 26-3 (1994) Standard
Room Fire Test
- Flash Ignition Temperature of 698°F (370°C) and Self
Ignition Temperature of 806°F (430°C) in accordance
with ASTM D1929
| Jurisdiction |
Canada* |
USA† |
| Flame Spread |
140 |
10 |
| Smoke Developed Over |
380 |
300 |
*FROM ULC FILE CR1762 †FROM
UL FILE R5817 (N)
Energy
Efficiency
- Thermal resistance of R22 (6" form unit) as calculated
with procedures in the ASHRAE Handbook—1997 Fundamentals
- Due to the moderating effect of the thermal mass of concrete,
thermal performance of the Arxx wall can exceed the performance
of a wood-framed wall insulated up to R-50
Sound Resistance
- Sound Transmission Classifications (STC) of 50 or higher
are easily attainable
High Wind Events Performance
- Minimal damage from impact testing in accordance with Dade
County Protocol PA 201-94 simulating hurricane storm damage
water vapor resistance
- In compliance with code requirements of 3.50 perms-in (200
ng/Pa•s•m2)
- Structural design considerations
- Structural integrity of the wall is a function of the reinforced
concrete
- Design as reinforced concrete in accordance with accepted
engineering principles
Building Requirements
- Interior face of the Arxx wall shall be protected from interior
spaces with minimum one layer ½" (12.7 mm) GWB in accordance
with local and national building codes
- Exterior face of the Arxx wall shall be protected with approved
exterior finish materials (i.e., masonry, siding, stucco, etc.)
- Below-grade waterproofing/drainage shall be in accordance
with local building codes and compatible with EPS
Code Evaluations
- ICC-ES Legacy Report NER-685
- ICC-ES Legacy Report ER-5119
- CCMC Report # 12641-R
- Massachusetts letter dated 03/25/96
- Wisconsin Approval # 200038-I
- California State license # TD 1349
- Texas Dept. of Insurance PER FR-35
- Miami–Dade County FL Notice of Acceptance # 02-1011.08
- Prince George’s County MD letter dated May 9, 2002
- St. Louis County MO letter dated 12/02/98
- City of Los Angeles RR 25468
- New York City MEA 281-02-M
Testing
- UL/ULC listing of Fire Resistance Ratings in accordance with
ASTM E119 and CAN/ULC-S101
- STC test results confirming performance in accordance with
ASTM E336-90 and E413-87
- R-Value determined by calculation consistent with ASHRAE
90.1
- Report of Standard Fire Room Test UBC Standard 26-3
- fastener withdrawal test reports conducted in accordance
with ASTM C473, D1037 and D1761-88
- ITS Listing documenting compliance with NBC of Canada requirements
for non-combustible cladding
- Report of successful completion of Canadian Fire Test CAN4-S124-M85
- Dade County Impact Test PA 201-94
Find a Distributor
Need Project Info?

2007 Awards
Toledo Design & Development
Cronin Contracting
Member
Canadian Green Build Council (www.cagbc.org)

Member
U.S. Green Build Council (www.usgbc.org)